1747 RM001 EN P PDF

Also, do not expose processor modules to surfaces or other areas that may typically hold an electrostatic charge. Electrostatic charges can alter or destroy memory. For general recommendations concerning installation safety requirements and safety related work practices, refer to the requirements specific to your region. La mise en garde suivante porte sur une utilisation en environnement dangereux.

Author:Gardatilar Doukazahn
Country:Kuwait
Language:English (Spanish)
Genre:Travel
Published (Last):9 March 2008
Pages:152
PDF File Size:1.73 Mb
ePub File Size:7.29 Mb
ISBN:203-1-17455-260-7
Downloads:19470
Price:Free* [*Free Regsitration Required]
Uploader:Tomuro



SLC Instruction Set. Reference Manual. Solid state equipment has operational characteristics differing from those of electromechanical equipment. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc.

The examples and diagrams in this manual ar e included solely for illustrative purposes. Because of the many variables and requir ements associated with any particular installation, Rockwell Automation, Inc. No patent liability is assumed by Rockwell Automation, Inc. Reproduction of the contents of this manu al, in whole or in part, without written permission of Rockwell Automation, Inc.

Throughout this manual, when necessary, we use notes to make you aware of safety considerations. Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. Identifies information that is critical for successful application and understanding of the product.

Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequences. Labels may be located on or inside the equipment for example, drive or motor to alert people that dangerous voltage may be present.

Labels may be located on or inside the equipment for example, drive or motor to alert people that surfaces may be dangerous temperatures. Summary of Changes. The information below summarizes the changes to this manual since the last printing. To help you find new and updated information in this release of the manual, we have included change bars as shown next to this paragraph.

The table below lists the sections that document new features and additional or updated information about existing features. For This Information. See Page. Addition of Table Table of Contents.

Who Should Use This. Purpose of. Common Techniques Used in This Manual. Chapter 1. File Structure. Status File.

File S Bit Data File B Timer Data File Addressing Structure. Counter Data File Elements. Entering Parameters. Addressing Structure.

Control Data File R Integer Data File N Float Data File F Chapter 2. Basic Instructions. About the Basic Instructions. Bit Instructions Overview. Examine if Closed XIC. Examine if Open XIO. Output Energize OTE. Using OTL. One-shot Rising OSR. Timer Instructions Overview. Timer On-delay TON. Using Status Bits. Timer Off-delay TOF. Retentive Timer RTO. Using Status Bits Counter Instructions. Count Up CTU.

How Counters Work. Count Down. High-speed Counter HSC. High-speed Counter Data. High-speed Counter Operation. Reset RES. Chapter 3. Comparison Instructions. About the Comparison Instructions. Equal EQU.

Comparison Instructions Overview. Using Indexed Word Addresses. Using Indirect Word Addresses. Not Equal NEQ. Less Than LES. Greater Than GRT. Masked Comparison for Equal. Limit Test LIM. Chapter 4. About the Math Instructions.

Math Instructions Overview. Updates to Arithmetic Status. Updates to the Math Register, S and S Using Floating Point Data File. Subtract SUB. Math Overflow Selection Bit. Multiply MUL. Divide DIV. Updates to the Math Registers, S and S Double Divide DDV.

Clear CLR. Square Root SQR. Scale with Parameters SCP. Application Examples. Scale Data SCL. Ramp Instruction RMP. Instruction Operation. RMP Equation. Continuous Operation. Compute CPT. Learn more about Scribd Membership Home. Much more than documents. Discover everything Scribd has to offer, including books and audiobooks from major publishers.